Leak Test System FAQ
Made in the USA
EAC in North Wales, PA represents LeakMaster in Pennsylvania, New Jersey, Maryland, Delaware and Virginia. Call (215) 855-8777 or email sales@eac-co.com.
Getting reliable results
Why is our leak tester giving false rejects?
Most often the seal tooling: a fixture that leaks at the seal, flexes under pressure or adds volume. Temperature and part variation also play a part. LeakMaster designs tooling with the test to address this.
How do we know the tester is still accurate?
Verify it regularly against a calibrated leak standard, which leaks at a known rate. LeakMaster makes and calibrates these under A2LA accreditation.
Can LeakMaster prove the test on our parts first?
Yes. EAC arranges part sampling before you commit to equipment.
Service and support
Does LeakMaster provide calibration and service?
Yes: in-house calibration accredited to ISO/IEC 17025:2017 by A2LA, on-site service and technical support.
Should we choose the leak test, or leave it to our machine builder?
Choose it yourselves, early. You carry the validation burden, so the method and tooling should be decided with your quality team.
Who is the LeakMaster rep for Pennsylvania, New Jersey, Maryland, Delaware and Virginia?
EAC (Engineered Automation Components), North Wales, PA.